Release Notes

Home

 

Up

 

Install Files: 

Note it is not necessary to install software every time a new exec is produced. Most of the time just copy the exec from the current list below. The release notes will advise you if an install is required.

PPEViewer V2.0 Configuration Database    This is the Access Database that holds the current setting for V2.0 (203). It contains news tables for the email.

(Release date: 27/4/2009)

PPEViewer Installer V215    This is the install zip file for the PPEViewer. It includes the database registry msado28.tlb for the saving of configuration settings. The install should be in Program Files\PPEViewer.

This install puts an old executable into the install path. Always get the latest exec below and copy over this old exec.

(Release date: 27/4/2009)

 

 

Current Version:   

 

     PPEViewer V2.2 (299)    (Release date: 11/6/2013)

Minor release:    Fixed Satellite Input.

Added a state change where corruption can stop the state machine from advancing at the start of a batch

 

     PPEViewer V2.2 (297)    (Release date: 4/3/2013)

Minor release:    Fixed Satellite TCP Input.

Removed CNET debugging.

Added 300mSecond timer to the serial input.

 

PPEViewer V2.2 (296)    (Release date: 24/1/2013)

 

Minor release:    Fixed TCP Input PPE automatic start-up.

 

PPEViewer V2.2 (295)    (Release date: 9/2/2012)

 

Minor release:    Fixed Log file location.

                           Added CNET debug in the Satellite Tab.

 

PPEViewer V2.2 (285)    (Release date: 18/08/2010)

 

Minor release:    Fix stats report

The stats are now cleared every hour. The code below creates the stats.

'Daily Stats
If DailyStatsTimer < Now Then
    DailyStatsTimer = Date + 1 + #1:00:00 PM#
    UpdateStatsFile
    HourlyStatsPeriod = Date + #1:00:00 PM#
    'emails the stats file then clears it
    SendStatsFile
    EmailStatsFile
    ClearViewer
Else
    'Collect stats hourly
    If HourlyStatsPeriod < Now Then
        HourlyStatsPeriod = Now + #1:00:00 AM#
        UpdateStatsFile
        ClearViewer 'update email list with the stats file then clears it
    End If
End If

 

PPEViewer V2.2 (284)    (Release date: 17/08/2010)

 

Major release:    E2054 Redundant operation

The Viewer now has been extensively modified to operate on redundant E2054 systems. The normal viewer functionality for the E2000 products remains the same with the following exception.

When using this release make sure the E2000 option is selected.

 

New stats email:

Previous versions did not clear the stats except on restart or clicking the reset or backup buttons.

The stats are now reported then cleared every hour. Each report is concatenated into a single email which is sent at 1pm every day.

 

 

PPEViewer V2.2 (250)    (Release date: 15/01/2010)

 

Minor release:    Changed Satellite decoder operation

Improved Satellite Asynchronous Decoder

The Viewer now has been changed to operate with the new MTEL PPE Encoder for satellite transmission. The Asynchronous data stream has no EOT character sequence therefore a 300millisecond data absence timer was added to test for the end of the data stream. The display has been changed to make the batches more distinguishable.

The previous MC01 device had NULL markers at the end of transmission, which allowed the previous version to operate correctly.

The window below shows the decode and the Batch Control label indicating the data stream has expired.

The state machine has been dramatically increased in speed since the bit stuffing for the MC01 is no longer required. The data runs pure POCSAG decode in ASCII format with fixed 32 bit boundaries.

 

 

 

 

 

 

 

 

Changed System Configuration tab

The system configuration tab has been changed to make the logging more intuitive. The master root directory is selectable however the file names for the satellite decoder and the E2000 monitor are dedicated.

 

 

Previous Versions:

27/06/2009

Major release:    Added support for remote monitoring of the E2054.

The Viewer now communicates to three different hardware devices.

  • PPE Encoder (Hutchison)
  • Satellite Decoder
  • E2054 Paging System

The Viewer has been enhanced to handle remote MTEL paging systems which have the ability to handle multiple data streams over a single TCP or wireless broadband connection. The multiple data streams include a decode of the paging data stream, priority and normal paging inputs and monitoring of the local paging processor (E2050) debug data stream. The data streams are multiplexed over the one data channel and have an embedded protocol to decipher the data streams.

The protocol is switched on or off by a single option. Normally the PPEViewer uses the E2000 Control which only monitors the standard E2050 processor debug data stream. Select this on start-up and close the program to save the setting to registry. On the next and future start-ups the E2000 Control will be selected automatically.

The E2054 Control adds the new MTEL switch protocol onto the normal data stream. The PPEViewer will not work if this protocol is selected and it is directly connected to the PPE. The E2054 Control also enables the new Messaging tab. This tab only works on the E2054 Paging Systems at this point in time.

The selection is made in the System Configuration tab as shown below.

 

 

 

 

Added Reset WD warning

The reset command to the Processor is now tested with a message box to ensure the selection is not made accidentally.

 

Added Operating System Detection:

The Viewer operates slightly differently depending on the Windows OS.

A control has been added to detect this automatically so the program can adjust parameters depending on the OS at start-up.

Unfortunately it will require a reinstall if the Viewer has been operating before this release.

Go to the install page to get the latest install. Click Here.

 

Bug Fixes:

Email Support. Fixed bug where the second and third recipient of the emails in the AlertMatrix Table were getting no subject or text information.

Refresh Enhancement. Made the refresh simpler using just one command button "Refresh". This button immediately clears the display then when the response to the command is deciphered it then populates the fields.

The set clock time is manually set by the small "S" command button next to the E2050 Clock time display. Whenever the Viewer is connected to the E2050 the time update is automatically sent to the E2050 every hour.

 

PPEViewer V2.2 (203)    27/04/2009

Minor release:    Fixed Batch under runs stat

 

PPEViewer V2.2 (201)    13/03/2009

Major release:

Added Email Support.    See the Email tab instructions to use this feature.

Added circular backup files.    

The backup files are created daily at 11:30pm and one is created for each date of the month. If a previous day file exists it is deleted. This simply means there is a month of backup data at any one time. An example of the files is shown below.

 

Added Quick Pick Server Support.   

This provides a single click selection to configure the Viewer to a known profile. The profiles are stored in a simple list and selecting the profile automatically sets up the Viewer to the correct port or TCP socket. The table is in the mtelppeviewer.mdb and is called "Server".

There are currently no instructions for this feature. Use Access to change the values to desired settings. Below is an example of the table.

The information appears in a drop down list in the PPE Monitor configuration frame as shown below.

 

PPEViewer V2.2 (188)    9/10/2008

Removed STATS update every minute.

 

PPEViewer V2.2 (187)    8/10/2008

The main change in this version is the addition of the version and frequency information in the E2000 configuration display. Hitting the refresh will display all the information for E2000 firmware V2.87 and up.

The second change was the merge of the old Tone Tab into the main PPE Queue tab.

Tone information can be quickly checked by clicking the T command button in the Queue Totals frame.

The Tone Queue totals are now in the same frame as the normal queue totals as shown below.

 

 

PPEViewer V2.0 (182)    16/9/2008

Warning: Previous versions are now defunct and are not backward compatible.

Some of the debug has been changed to improve E2000 internal processing. This meant the debug format had to be changed, making it incompatible with all older versions of PPEViewer.

The main change in this version is the addition of the power monitoring.

 

PPEViewer V2.0 (170)    1/9/2008    Major changes are.

Warning: Previous versions are now defunct and are not backward compatible.

Some of the debug has been changed to improve E2000 internal processing. This meant the debug format had to be changed, making it incompatible with the older version of PPEViewer.

The main change in this version is the addition of the commands to the E2000. These commands provide PPEViewer interaction with the E2000. Currently these are

  • Hardware reset
  • Time Set/Request
  • E2000 Configuration (currently read only)

The tone buffer is now visible via the Tone Queue Tab.

The queue displays time in the queue in seconds. It also averages the time and displays it along with the maximum time in queue.

Finally a independent reset and backup button has been added for manual resetting of the PPEViewer Counters and times and Queue information.

  •     Added Tone Queue Tab.
  •     New commands to the E2000.
  •     New E2000 configuration frame.
  •     New "Time in Q" and average TIQ labels.

Other changes include

  •     Added reset and backup buttons.

 

PPEViewer V2.0 (120)    20/5/2008    Minor changes are.

  •     removed nulls from the TCP and serial input streams.

 

PPEViewer V2.0 (119)    20/5/2008    Minor changes are.

  •     Added separate log window.
  •     Displays sequence numbers.
  •     Displays commands between systems.
  •     Queue display indicates sync to hardware.
  •     Added new flooding batch controls.

The main emphasis on this release is the display of the sequence numbers. These numbers indicate the age of the message where the lowest is the oldest number. The new binary release for the E2050 uses the sequence to decide which baud rate to start a batch. When the sequence reaches 5000 it is reset back to 200. Messages in the queue are adjusted by this change.

There are also new batch controls. The new binary release has created two sets of rules. The normal queuing logic as in previous releases, and now a separate set of rules when the E2050 becomes flooded with messages.

The separate log window allows the user to view the queue and the logs simultaneously.

 

PPEViewer V2.0 (110)    Major changes are.

  •     Logging is now optional.
  •     Logging is now backed up.
  •     PPE settings have been automated.
  •     Satellite settings have been automated.

Other changes include

  •     Added label change colour to indicate which buffer sets the current Q.
  •     Added raw log to the PPEViewer front tab.
  •     Re-arranged Satellite Output Config tab.
  •     Added serial config to satellite output.
  •     Added logging checkboxes.
  •     Output Satellite frame now has multiple outputs.

(Release date: 21/9/2007)

 

PPEViewer V2.0 (102)    Two major changes have been made.

  •     Satellite decoder has a sizeable window including a maximise ability
  •     The Viewer now starts from a configuration database.
  •     New operational file structure.

The installation procedure is documented at PPEViewer Install.

Other changes include

  •     Bug fix on the FOS display.
  •     Change to numeric processing on the satellite decode.
  •     F1/F2 system decoder for PPE.
  •     Bug fix on TCP server re-listen after a disconnect.
  •     Satellite decoder has bit indicator in config.
  •     Capcode can be formated in Satellite decoder.
  •     Satbusfile debug is turned on by config.

(Release date: 6/9/2007)

 

PPEViewer V2.0 (92)    The PPEViewer satellite decode now has numeric processing. It appends "Numeric Stg" when it decides the output is a numeric rather than a Alpha message. The decision is based on the presence of a "~" in an alpha message.

The program now has some settings stored in the mtelppeviewer.mdb database. This operates like a registry of configuration settings. Currently it must reside in c:\mtelsys. The installer copies it into the current application directory.

The current settings are for the satellite serial and TCP inputs, the TCP server output, and output format check boxes.

The serial configuration has been changed from a single text box to two text boxes for port and baud rate. This gives a better range of settings than the previous style.

The PPEViewer includes the new commands OSTXING. This packet between the systems indicates to the state of transmission so that a decision can be made to key up if priority appears in both systems.

(Release date: 4/9/2007)

 

PPEViewer V2.0 (90)    The satellite decode now has a TCP server. There has been a modification to the incoming byte stream to correct for bit slip. The slip is reset to 0 bits at the start of each batch and is set by the Sync detection. The debug indicates the level of slip.

(Release date: 30/8/2007)

 

Latest PPEViewer V2.0 (89)    Added more debug and FOS (from other system) and TOS (to other system) indications.

(Release date: 28/8/2007)

Latest PPEViewer V2.0 (88)    Added satbusfile in c:\logs. This file captures the raw data and has embedded decode from the normal screen for reference. This file is only intended for the debug of TCP and serial data streams. It will be disabled by default after the streams are correctly operating.

The file is opened on startup and destroys the previous file contents.

(Release date: 27/8/2007)

 

PPEViewer V2.0 (87)    This version has updated Satellite Viewer functionality.

The Viewer now sends a formatted satellite decode output to a TCP device. The display mimics the formatted output.

(Release date: 22/8/2007)

 

PPEViewer V2.0 (83)    This version has updated PPEViewer functionality to conform to the PPE V2.20.

The PPE Viewer now accepts data from a TCP source.

The Viewer shows the new TMP and BUS commands. Fixed Que display from bus debug. Fixed serial input.

(Release date: 22/8/2007)

 

PPEViewer V2.0 (77)    This is the first official release for this application.

(Release date: 1/8/2007)

 

Home ] Up ]  
Copyright © 2012-2021 MTEL Communications Pty Ltd
Last modified: 01-Jun-2022